Pyramid DC Receiver Manual de instalación Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
Page 9
Installation Manual Pyramid DC Receiver
CONNECTING AUXILIARIES
Up to four auxiliaries can be connected and powered by the DC receiver via CON9, CON10 and CON11. Auxiliaries are
connected to CON10 and CON11, and a power supply is connected to CON9. The power supply is then switched through
to CON10 and CON11, thus powering the auxiliaries. A 240V AC mains power supply or a 24V AC power supply can be
used (although it should be noted that no auxiliary should draw over 2A at 240V AC). In both cases, the connection should
be made via the external terminal block, as it provides an in-line fuse for the circuit. It also provides more connection
space for the auxiliary return wires.
Using Figure 6 for 240V AC mains supplies and Figure 7 for 24V AC supplies, connect the auxiliaries to the receiver PCB.
CON 9
Snubber
Snubber
Snubber
Snubber
CON 10
AUX 1
AUX 2
AUX 3
AUX 4
AUX 1AUX 2AUX 3AUX 4
LIVE
NEUTRAL
CON 11
1 LIVE
3 NEUTRAL
Figure 6 - Auxiliary Connections with a 240V AC Mains Power Supply
CON 9
Snubber
Snubber
Snubber
Snubber
CON 10
AUX 1
AUX 2
AUX 3
AUX 4
AUX 1AUX 2AUX 3AUX 4
24 V A.C.
CON 11
1
3
Figure 7 - Auxiliary Connections with a 24V AC Power Supply
CAUTION
Connect lamps of greater than 300W using a separate relay as they can draw a surge current when they fail. This
may damage the DC receiver.
Always provide a separately fused mains spur for use with auxiliary devices.
Vista de pagina 8