Page 8
Pyramid DC Receiver Installation Manual
CONNECTING THE LENS DRIVE OUTPUTS
CON3 provides the lens drive outputs for focus, iris and zoom. The drive voltage is +12V DC at up to 100 mA. Refer to your
lens instructions and connect up your lens according to Figure 5.
CON6
CON3
ANTI-TAMPER
SWITCH
VIDEO
VIDEO
FOCUS
ZOOM -
IRIS +
FOCUS
ZOOM +
Figure 5 - CON3 Connections
ANTI-TAMPER CONNECTIONS
CON6 is used as an input for an external anti-tamper switch. It is connected in parallel with the built in anti-tamper switch
that is marked in Figure 2.
On the boxed variants, the built in anti-tamper switch is connected in a normally open (N/O) configuration. However, it is
fitted with a spring which is compressed when the module lid is closed, and thus closing the contact. When the lid is
removed, the input is opened and the alarm will be activated.
If the built in anti-tamper switch is not used, CON6 can be connected to an external anti-tamper switch. To do this, the
spring must be removed from the built in anti-tamper switch. CON6 should then be connected to the external anti-tamper
switch in a normally closed (N/C) configuration.