Pyramid DC Receiver Installation Manual
PY-COM NETWORK CARDS
If a PY-COM network card is fitted to the DC receiver, it can be configured by means of dip switches for use in both RS485
and RS422 networks. The dip switches for the different network types are shown below:
RS485 Mode
RS485 networks are 2-wire, bus-connected (also referred to as daisy-chain). In RS485 mode, the dip-switches on the
PY-COM will be set differently depending on where the unit is placed on the network. If the unit is the first or last in the
network, one network card in the unit will need to be set to provide biasing and termination as required. If the unit is central
to the network, all network cards will be set for use in a intermediate module.
Set the switches as required and wire the card to the network as shown in Figure 10. It is not necessary to make any
connections to the filter board.
ON
87654321
ON
87654321
ON
87654321
First Module
Intermediate Module
Last Module
White represen
ts
switch position
Not usedNetwork Not usedNetwork Not used
Network
Figure 10 - RS485 Switch Settings
RS422 Mode
RS422 networks use a 4-wire, point-to-point connection methodology. Set the switches as required and wire the card to
the network as shown in Figure 11. It is not necessary to make any connections to the filter board.
876543
Input
ON
21
Output
White represen
ts
switch position
Figure 11 - RS422 Switch Settings