Page 13
Installation Manual Pyramid Universal Dome Interface
CONNECTING A DENNARD DOME CAMERA
Dennard dome cameras are supplied with a flying lead connector which is connected to the socket on the top of the
dome housing. The flying lead connector is a multicore cable, and two of the wires are used specifically for network
connections. To connect these wires to the UDI, follow the steps below:
When connecting the UDI to a dome, reference should also be made to documentation provided with the dome.
1. Connect the yellow and green wires on the multicore cable to the UDIs Dome Data Connector. The green wire
should be connected to the - terminal and the yellow wire to the + terminal as shown below:
DENNARD DOME MULTICORE CABL
YELLOW WIRE
Connecting a Dennard Dome to the UDI
2. To address the dome camera it is necessary to remove the protective parts of the dome. First, carefully remove the
retaining screws and lift away the outer hemisphere.
3. Locate the two fixing screws and remove the inner shroud. The dome address switches should now be clearly
visible on the lower PCB.
4. Using the switches, set the dome address to 1. To do this, set both the blue switch and the yellow switch to the 0
position.
5. Refit the inner shroud and outer hemisphere, taking care to tighten the fixing screws.
CONNECTING A PANASONIC DOME CAMERA
Panasonic dome cameras are fitted with a multiple connector lead. There are five connectors on the lead, and each
connector is used for a different purpose (i.e., alarms, power, video, data). The wires from the UDIs Dome Data
Connector are connected to the dome using the data connector of this lead. To make this connection, follow the steps
below:
When connecting the UDI to a dome, reference should also be made to documentation provided with the dome.
1. Wire a female data connector with the wires from the UDIs Dome Data Connector as shown below. The pre-wired
male connector from the dome can then be inserted into the female connector to provide the data path between
dome and UDI.
RED
BROWN
ORANGE
YELLOW
GREEN
T (B)
GND
T (A)
R (B)
R (A)
DATA
RANSMISSION
DATA
RECEPTION
DATA CONNECTOR
CONNECTOR
FROM + TERMINAL
FROM - TERMINAL
WIRES FROM DOME DAT
CONNECTOR ON UDI:
Connecting a Panasonic Dome to the UDI
2. On the top of the dome camera, there is a block of eight dip switches labelled SW1. Use these switches to set the
dome address to 1. To do this, move the switch labelled 8 into the ON position and ensure that the other switches