Installation Manual Pyramid AC Receiver
POWER SUPPLY CONNECTIONS
The boxed variants of the AC receiver include a terminal block mounted on the metal base plate. This external terminal
block is used to earth the metal base plate and to connect the factory fitted 12V DC PSU to the mains power supply.
NEUTRAL
EARTH
LIVE
NEUTRAL
LIVE
GROUND
FUSED
SIDE
NON-FUSED
SIDE
Figure 13 - External Terminal Block
WARNING
Ensure that the power is switched off before connecting the mains wires.
The module must be earthed.
Do not connect additional mains devices to the fused side of the external terminal block.
Connect the Live, Earth and Neutral wires from the mains to Live, Earth and Neutral on the non-fused side of the external
terminal block. Switch on the mains power and any other power supplies that are being usedthe module now contains
live voltages.
When the power is switched on, LED1 lights to indicate the polarity of the 12V DC. If the polarity is correct it will light green,
and if it is incorrect, it will light red.